Jawa Barat - Bekasi

Hand Held 5 Gas Analyser OIML Class 1

Harga :
CALL
Merk :
KANE
Lokasi :
Jawa Barat - Bekasi
Dilihat :
750 Kali
Update Terakhir :
09-04-2011 11:12

Detail Produk

Hand Held 5 Gas Analyser OIML Class 1


The Kane Auto 4-1 & 5-1 Series Exhaust Gas Analysers are truly portable and set new standards of convenience and ease of use.


Measures CO, HC, O2, CO2, and Lambda (or AFR)


Weighing just 1kg, the handset fits comfortably in the hand and can run for up to 4 hours on its internal re-chargeable battery.


Ideal for emission diagnostics, tuning and regulated testing, where OIML Class 1 is specified

 
Product Features
  • Easy to use hand held 5 gas analyser.
  • Declaration of conformity to OIML R99 Class 1.
  • Certificate of calibration supplied.
  • Ideal for emissions diagnostics, tuning and regulated testing. Measures CO, HC, O2, CO2,NOx and Lambda (or AFR).
  • Fast warm up time and fast response time with higher output pump.
  • 5 language options built in
  • Store up to 250 Tests
  • RPM and oil temperature measurements plus accessories.
  • Prints via optional Infra-red printer.
  • PC compatible via RS232 for uploading stored data to PC for spreadsheet or graphical analysis and printing.

Kit contents:

  • Anlayser with protective rubber sleeve
  • Water trap and filter
  • 12v adapter cable
  • AC power supply/battery charger
  • Spare filters
  • Exhaust probe
  • Carry case
  • Manual
Specification

Parameter

Resolution

Accuracy

Range

Carbon Monoxide CO (Infra-red) 

0.01%

±5% of reading *1 ±0.06% volume *1

0-10%
Over-range 20%

Oxygen O2

(Fuel Cell)

0.01%

±5% of reading *1 ±0.1% volume *1

0-21%

Hydrocarbon HC *2
(Infra-red) 

1PPM

±5% of reading *1 ±12% volume *1

0-5,000ppm Over-range 20,000ppm

Carbon Dioxide CO2

(Infra-red)

0.1%

±5% of reading *1 ±0.5% volume *1

0-16% Over-range 20%

Oxides of Nitrogen NOx

(Electrochemical)

5 Gas Only

1PPM

0-4,000ppm ±4% or 25ppm *3

4,000-5,000ppm ±8% *3

0-5,000ppm

Oil Temperature Optional:

(only on some models) 

1°C/F

±2°C ±0.3% of reading
±4°F ±0.3% of reading

 

0-15°C

32-302°F

RPM Optional: (only on some models) 

1 RPM

50 RPM

200-6000RPM

 

Lambda
AFR Petrol
AFR LPG

 

 

0.001

0.01

 

 

0.8-1.2

11.76-17.64

12.48-1872

*1 Using dry gases at STP     *2 Applies

Optional Extras
  • KMIRP infra-red thermal printer
  • KANE ImPrint infra-red plain paper printer
  • RPM Clamp
  • Oil Temperature probe
  • Upgradeable to NOx or can be ordered as 5 gas analyser
  • PC Software

 
 

Permintaan Penawaran