Quick and simple set up
All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial start up. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need to perform fuel selection every time the analyzer is turned on |
---|
708: Combustion Efficiency Analyzer
• Measure CO, and temperature
• Calculate CO2, efficiency, excess air, and CO air free
708 Specifications | |
Carbon Monoxide (CO) Measurement | Range 0 to 10,000 ppm |
Resolution 1 ppm | |
Accuracy +/-5ppm or 5% of reading whichever is greater | |
Oxygen (02) Measurement | Range 0 to 25% |
Resolution 0.1% | |
Accuracy ±0.3% | |
Carbon Dioxide (CO2) | Range 0 to 25% |
Resolution 0.1% | |
Calculated Value | |
Nitric Oxide Measurement | N/A |
NOX Measurement | N/A |
Temperature Measurement | Range -40 to 1472°F, or -40 to 800°C |
Resolution 1°F or °C | |
Accuracy (K-type) ±0.3%, ±2°F or ±1°C | |
Draft/Pressure Measurement | Selectable Ranges mBar,kPa, and inH2O |
Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20 | |
Resolution 0.001 inH2O | |
Accuracy ±0/5% fsd | |
Gross/Net Efficiency | Range 0 to 100% |
Resolution 0.1% | |
Calculated Value | |
CO/CO2 Ratio | Range 0 to 0.999 |
Resolution 0.001 | |
Calculated Value | |
Operating Temperature | 14°F to 122°F (-10°C to 50°C) |
Battery Type | 1.5V AA (3) |
Selectable Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, |
Coke, Butane, Wood, Bagasse | |
Display Type | Backlit 3 line LCD |
Data Storage | 50 Locations |
Data Logging | N/A |
Print Capability | Yes, via optional IR printer (A740) |
PC Communication | N/A |
Date & Time Function | 24 Hour Real Time Clock |
Dimensions | 200mm x 90mm x 60mm |
Weight | 500g |
Conformity | BS7927 (and the draft BS7967) |
708 Applications | |
Tuning of residential and furnaces and domestic boilers | |
Ambient and stack testing for CO | |
CO safety measurements in and around combustion sources | |
Temperature checking, including superheat and hydronic differential temperatures | |
708 Combustion Accessories OPTION | |
A765: Rubber Boot | : Protective rubber boot for the following meters: 707, 708. 709, 709R, 712 and 714 |
A787: Carrying Case | : Soft carrying case with shoulder strap |
GK11M: K-type thermocouple | : Fiberglass insulated multi-purpose beaded thermocouple probe. |
A763: Mini pump protection filter | : Provides additional protection for the pump and strain relief for the flue probe. |
A770: Flue Probe | : Flue probe w/ water trap and filter 7.5 foot |