Jawa Barat - Bekasi

Carbon Monoxide Analyzers A771

Harga :
CALL
Merk :
Test Products International,Inc
Pengiriman :
3 hari sejak pembayaran
Lokasi :
Jawa Barat - Bekasi
Dilihat :
729 Kali
Update Terakhir :
09-04-2011 16:36

Dapatkan Spesifikasi Harga Carbon Monoxide Analyzers A771 Produk Terbaik dari CV.ANDALAN PRIMA SEJAHTERA pH/conductivity/TDS/DO/Temperature Meter, oscilloscope, multimeter, weather station, particulate air monitor,dust sampler

Detail Produk

Carbon Monoxide Analyzer TECH Tips

Don’t expose yourself to Carbon Monoxide!

Review the list below for the maximum allowable exposure limits and symptoms developed with CO inhalation.

9ppm: The maximum allowable concentration for short term
exposure in a living area according to ASHRAE

50ppm: The Federal OSHA standard for continuous exposure in any eight hour period.

200ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after 2-3 hours.

400ppm*: Frontal headaches within 1-2 hours, life threatening after 3 hours. Maximum allowable limit in flue gas according to EPA and AGA.

800ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within 2 hours. Death within 2-3 minutes.

1600ppm*: Headache, dizziness, and nausea within 20 minutes.
Death within 1 hour.

3200ppm*: Headache, dizziness, and nausea within 5-10 minutes.
Death within 30 minutes.

6400ppm*: Headache, dizziness, and nausea within 1-2 minutes.
Death within 10-15 minutes.

12800ppm*: Death within 1-3 minutes.

* With exposure to this concentration and higher the effects can vary depending on size, age, sex, and health.

A771: CO Adapter for DMMs

The A771 is a CO adapter designed to work with your DMM to measure ambient air CO. Can also be used as a personal COalarm.
  • Built-in alarm is preset to 30ppm. Setting can be set by user.
  • Use with any DMM with minimum 2 1/2 digit LCD, 2 or 4Volt DC range and 10M Ohm or greater input impedance.
  • Detect CO levels from 0-1999 ppm, with resolution as low as 0.1 ppm and ±5% of reading accuracy.
  • Soft pouch included
A771 Specifications
Carbon Monoxide (CO) Measurement Range 0 - 1999ppm
Accuracy ±5ppm or 5% of reading whichever is greater
Resolution 1ppm
Output 1mVDC / 1ppm CO into 10M Ohm impedance
IR Printer Port No
Flue Probe No
Internal Pump No
Combustible Gas Leak Detection No
Backlight N/A
Alarm Audible
Power Supply 9V Alkaline Battery
Dimensions 6.5” x 2.1” x 1.2”
(165 x 55 x 30 mm)
>Weight 7.23oz (205g)
A771 Applications
Ambient CO safety checks


Permintaan Penawaran